DSCPS Series

    Control and Protection Switch

    (1-125A)

    Concise Efficient Safe Comprehensive

    PRODUCT OVERVIEW

    DSCPS series control and protection switch is a comprehensive intelligent product integrating various functions of circuit breaker (fuse), contactor, overload (overcurrent, phase failure) protection relay, starter, isolator, etc. It can protect the system from short-circuit, overload, and leakage protection, and it is widely used in industry and other fields to protect the circuits and realize intelligent control and management.

    MULTIPLE PROTECTION FUNCTIONS

    D5CPS series control and protection switch has many functions such as phase failure, overcurrent, locked rotor, blockage, short circuit, undercurrent, overvoltage, undervoltage, residual current protection, three-phase unbalance, phase loss, isolation, startup timeout, fire protection, fault signal output, and remote shunt, etc., providing electrical protection for the equipment.

    FAULT MEMORY FUNCTION

    DSCPS series control and protection switch has the functions of remote automatic control and local direct manual control. Various parameters can be set and queried; based on MCU's ERPROM storage memory technology, parameters can be saved after power failure. It has a fault memory function, which is convenient for fault query and analysis.

    Technical parameters

    DSCPS series control and protection switch technical parameters

    Shell frame grade Rated current
    of main body
    Breaking Casing grade
    capacity (kA)
    Rated operating
    current of
    controller Ie (A)
    Rated operating
    current adjustment
    range of
    controller Ir (A)
    Control power range of
    400V (kW) (kW)
    Use category
    45 16 15 1 0.2-1 0.12-0.37 Motor type AC-44
    3 1-3 0.55-1.5
    6 2.4-6 1.1-3
    10 4-10 1.5-4
    16 6.4-16 3-7.5
    45 20 10-20 5.5-11
    32 12.8-32 5.5-15
    45 16-45 7.5-18.5
    125 125 35 50 20-50 7.5-22
    63 25.2-63 11-30
    80 32-80 16-37
    100 40-100 22-45
    125 50-125 22-55

    DSCPS2 series control and protection switch technical parameters

    Shell frame grade Rated current of
    main body
    Breaking capacity(kA) Rated operating current
    of controller Ie (A)
    Rated operating
    current adjustment
    range of controller Ir (A)
    Control power
    range of 400V (kW) (kW)
    Use category
    45 16 50kA 1 0.2-1 0.12-0.37 Motor type AC-44
    4 1-4 0.55-1.5
    6.3 2.4-6.3 1.1-3
    12 4-12 1.5-4
    16 6.4-16 3-7.5
    45 32 12.8-32 5.5-15
    45 16-45 7.5-18.5
    125 63 45 18-45 7.5-18.5
    50 20-50 7.5-22
    63 25.2-63 11-30
    125 100 40-100 22-37
    125 50-125 22-55
    Selection table

    DSCPS Series Control and Protection Switch

    DSCPS 45 H 33 M 45 FK M B F
    Product code Shell frame
    grade
    Breaking
    capacity (kA)
    Number of
    poles and
    protection
    Tripping
    device code
    Rated
    current
    Auxiliary
    code
    Control
    voltage
    Display
    code
    Additional
    features
    DSCPS:
    Control and Protection Switch
    45A
    125A
    Ics:15kA
    Ics:35kA
    33: 3 pole 3 protection
    30:3 pole without protection
    M: Motor protection1A
    3A
    6A
    10A
    16A
    20A
    32A
    45A
    50A
    63A
    80A
    100A
    125A
    FK: 4 opened, 3 closed
    + 1 group conversion
    + 1 group fault alarm
    + 1 group short-circuit alarm
    M:AC220V B:Digital F:Fire protection
    L:Leakage
    FL:Fire protection+Leakage

    Note: Isolation function is standard setting

    DSCPS2 Series Control and Protection Switch

    DSCPS2 45 H 33 M 45 FK M B F
    Product code Shell frame
    grade
    Breaking capacity (kA) Number of
    poles and
    protection
    Tripping
    device code
    Rated current Auxiliary
    code
    Control voltage Display code Additional
    features
    DSCPS2:
    Control and Protection Switch
    45A
    125A
    Ics:50kA 33: 3 pole 3 protection
    30:3 pole without protection
    M: Motor protection 1A
    4A
    6.3A
    12A
    16A
    32A
    45A
    50A
    63A
    100A
    125A
    FK: 2 opened and 2 closed
    + 1 group conversion
    + 1 group short-circuit alarm
    M:AC220V B:Digital
    E:LCD
    F:Fire protection
    L:Leakage
    T:Communication
    FT:Fire protection+Communication
    TL:Communication+Leakage
    FLT:Fire protection+Leakage +Communication

    Note: Isolation function is standard setting, fire protection and leakage function are optional.

    Technical Parameters


    DSCPS Series Control and Protection Switch

    • Rated current of main body:16

      Breaking capacity (kA) :15kA

      Rated operating current of controller Ie (A) :1A、3A、6A、10A、16A

      Rated operating current adjustment range of controller Ir (A) :0.2-1A、1-3A、2.4-6A、4-10A、6.4-16A

      Control power range of 400V (kW) :0.12-0.37kW、0.55-1.5kW、1.1-3kW、1.5-4kW、3.7-5kW

      Use category: Motor type AC-44

    • Rated current of main body :45

      Breaking capacity (kA) :15kA

      Rated operating current of controller Ie (A) :20A、32A、45A

      Rated operating current adjustment range of controller Ir (A) :10-20A、12.8-32A、16-45A

      Control power range of 400V (kW) :5.5-11kW、5.5-15kW、7.8-18.5kW

      Use category: Motor type AC-44

    • Rated current of main body :125

      Breaking capacity (kA) :35kA

      Rated operating current of controller Ie (A) :50A、63A、80A、100A、125A

      Rated operating current adjustment range of controller Ir (A) :20-50A、25.2-63A、32-80A、40-100A、50-125A

      Control power range of 400V (kW) :7.5-22kW、11-30kW、16-37kW、22-45kW、22-55kW

      Use category: Motor type AC-44

    DSCPS2 Series Control and Protection Switch

    • Rated current of main body :16

      Breaking capacity (kA) :50kA

      Rated operating current of controller Ie (A) :1A、4A、6.3A、12A、16A

      Rated operating current adjustment range of controller Ir (A) :0.2-1A、1-4A、2.4-6A、4-12A、6.4-16A

      Control power range of 400V (kW) :0.12-0.37kW、0.55-1.5kW、1.1-3kW、1.5-4kW、3.7-5kW

      Use category: Motor type AC-44

    • Rated current of main body :45

      Breaking capacity (kA) :50kA

      Rated operating current of controller Ie (A) :32A、45A

      Rated operating current adjustment range of controller Ir (A) :12.8-32A、16-45A

      Control power range of 400V (kW) :5.5-15kW、7.8-18.5kW

      Use category: Motor type AC-44

    • Rated current of main body :63

      Breaking capacity (kA) :50kA

      Rated operating current of controller Ie (A) :45A、50A、63A

      Rated operating current adjustment range of controller Ir (A) :18-45A、20-50A、25.2-63A

      Control power range of 400V (kW) :7.8-18.5kW、7.5-22kW、11-30kW

      Use category: Motor type AC-44

    • Rated current of main body :125

      Breaking capacity (kA) :50kA

      Rated operating current of controller Ie (A) :100A、125A

      Rated operating current adjustment range of controller Ir (A) :40-100A、22-37A

      Control power range of 400V (kW) :22-37kW、22-55kW

      Use category: Motor type AC-44

    Selection table


    • Product code :DSCPS: Control and Protection Switch

      Casing grade:45A、125A

      Breaking capacity (kA) :Ics:15kA、Ics:35kA

      Number of poles and protection:33: 3 pole 3 protection 、30:3 pole without protection

      Tripping device code:M: Motor protection

      Rated current:1A、3A、6A、10A、16A、20A、32A、45A、50A、63A、80A、100A、125A

      Auxiliary code:FK: 4 opened, 3 closed+ 1 group conversion + 1 group fault alarm + 1 group short-circuit alarm

      Control voltage:M:AC220V

      Display code:B:Digital

      Additional features:F:Fire protection、L:Leakage 、FL:Fire protection+Leakage

    • Product code :DSCPS2: Control and Protection Switch

      Casing grade:45A、125A

      Breaking capacity (kA) :Ics:50kA

      Number of poles and protection:33: 3 pole 3 protection 、30:3 pole without protection

      Tripping device code:M: Motor protection

      Rated current:1A、4A、6.3A、12A、16A、32A、45A、50A、63A、100A、125A

      Auxiliary code:FK: 2 opened and 2 closed+ 1 group conversion + 1 group fault alarm

      Control voltage:M:AC220V

      Display code:B:Digital 、E:LCD

      Additional features:F:Fire protection、L:Leakage 、T:Communication、FT:Fire protection+Communication、TL:Communication+Leakage 、FLT:Fire protection+Leakage +Communication