NPM10 Series

    Intelligent Control Equipment

    Intelligent Fast Safe Comprehensive

    PRODUCT OVERVIEW

    NPM10 series product is a new type of powerful and diversified intelligent analog dynamic indication equipment designed for the control requirements of power switchgear. The product is suitable for 3-35KV indoor switchgear, middle-placed switchgear, handcart switchgear, fixed switchgear, ring network switchgear and other switchgears. It can replace the current primary circuit simulation, live display, automatic heating and dehumidification controller, which is a product that integrates several of functions, such as circuit breaker opening and closing status indication, energy storage indication, grounding switch indication, position indication and RS485 communication interface, etc.

    PRODUCT CHARACTERITICS

    Accurate judgment and quick feedback

    The front end of the product can be configured with an isolation switch or its own isolation function to ensure that there are obvious line disconnection points to protect personal safety during maintenance.

    Strong safety, reliability and stability

    Equipped with the human body sensor cabinet lighting function, voice mistake proof prompt function, heating and load disconnection alarm function.

    Powerful function, flexible customization

    Adopts industrial-grade electronic components with unique anti-interference technology, which can provide highly customized service to find the most suitable product for each project.

    High degree of intelligence

    Designed in an integrated circuit with an advanced processing unit and digital sensor technology. Not only can it locally monitor the operation status of the high-voltage switchgear in real time, but also upload the data to the monitoring system through network technology, which helps the system to analyze the trend of various data of the switchgear, detect potential faults in time, and facilitate the intelligent development of the substation and distribution network.

    Technical Parameters

    Function model NMP10-KG NMP10-KS NMP10-KY
    Dynamic analog diagram
    Voice prompt
    Live display and lock
    Electric testing and phase verification
    Temperature and humidity fixed monitoring —— ——
    Temperature and humidity digital display —— ——
    Temperature and humidity LCD display —— ——
    Opening and closing change-over switch
    Local-remote change-over switch
    Manual energy storage change-over switch
    Lighting switch in switchgear ——
    Pre-opening and pre-closing indication ——
    Integrity indication of opening and closing circuit —— ——
    Voltage value display of opening and closing circuit —— ——
    Measurement display of main circuit current, voltage, power and other electrical parameters —— —— □(Alternative)
    Online temperature measurement of contacts and cable joints —— ——
    Human body sensor probe
    RS485 communication
    Load disconnection alarm
    Hole size 220x165mm 220x165mm 220x165mm

    Note:■ Standard configuration、□ Optional configuration、— Non-supported configuration

    Selection table

    NMP10 K Y Additional functions
    Product code Product category Display mode Additional functions
    NMP10:
    Switchgear Indication and Manipulation Equipment
    K:witchgear intelligent control device
    Z:Switch status analog indicator
    S:Digital display
    Y:LCD display
    G:Without display
    D:Electric testing and phase verification
    P:Wireless temperature measurement
    C0:Data measurement
    F:Pre-opening and pre-closing indication
    S:Self-testing
    B:Independent locking power supply
    C:Independent locking output
    W:Over-temperature alarm
    T:Over-humidity alarm
    Z1:DC opening measurement
    Z2:DC closing measurement
    M:Analog output
    None:no addtional function

    Technical Parameters


    • Dynamic analog diagram:Standard configuration

      Voice prompt:Standard configuration

      Live display and lock:Standard configuration

      Electric testing and phase verification:Optional configuration

      Temperature and humidity fixed monitoring:Standard configuration

      Temperature and humidity digital display :None

      Temperature and humidity LCD display:None

      Opening and closing change-over switch:Standard configuration

      Local-remote change-over switch:Standard configuration

      Manual energy storage change-over switch:Standard configuration

      Lighting switch in switchgear:Standard configuration

      Pre-opening and pre-closing indication:None

      Integrity indication of opening and closing circuit:None

      Voltage value display of opening and closing circuit:None

      Measurement display of main circuit current, voltage, power and other electrical parameters :None

      Online temperature measurement of contacts and cable joints:None

      Human body sensor probe:Optional configuration

      RS485 communication:Standard configuration

      Load disconnection alarm:Standard configuration

      Hole size:220x165mm

    • Dynamic analog diagram:Standard configuration

      Voice prompt:Standard configuration

      Live display and lock:Standard configuration

      Electric testing and phase verification:Optional configuration

      Temperature and humidity fixed monitoring:None

      Temperature and humidity digital display :Standard configuration

      Temperature and humidity LCD display:None

      Opening and closing change-over switch:Standard configuration

      Local-remote change-over switch:Standard configuration

      Manual energy storage change-over switch:Standard configuration

      Lighting switch in switchgear:Standard configuration

      Pre-opening and pre-closing indication:Standard configuration

      Integrity indication of opening and closing circuit:None

      Voltage value display of opening and closing circuit:None

      Measurement display of main circuit current, voltage, power and other electrical parameters :None

      Online temperature measurement of contacts and cable joints:None

      Human body sensor probe:Optional configuration

      RS485 communication:Standard configuration

      Load disconnection alarm:Standard configuration

      Hole size:220x165mm

    • Dynamic analog diagram:Standard configuration

      Voice prompt:Standard configuration

      Live display and lock:Standard configuration

      Electric testing and phase verification:Optional configuration

      Temperature and humidity fixed monitoring:None

      Temperature and humidity digital display :None

      Temperature and humidity LCD display:Standard configuration

      Opening and closing change-over switch:Standard configuration

      Local-remote change-over switch:Standard configuration

      Manual energy storage change-over switch:Standard configuration

      Lighting switch in switchgear:None

      Pre-opening and pre-closing indication:Standard configuration

      Integrity indication of opening and closing circuit:Standard configuration

      Voltage value display of opening and closing circuit:Standard configuration

      Measurement display of main circuit current, voltage, power and other electrical parameters :Optional configuration(Alternative)

      Online temperature measurement of contacts and cable joints:Optional configuration(Alternative)

      Human body sensor probe:Standard configuration

      RS485 communication:Standard configuration

      Load disconnection alarm:Standard configuration

      Hole size:220x165mm

    注:■Standard configuration、□ Optional configuration、— Non-supported configuration

    Selection table


    • Product code :NMP10:Switchgear Indication and Manipulation Equipment

      Product category:K:Switchgear intelligent control device、Z:Switch status analog indicator

      Display mode:S:Digital display、Y:LCD display、G:Without display

      Additional features:D:Electric testing and phase verification、P:Wireless temperature measurement、C0:Data measurement、F:Pre-opening and pre-closing indication、S:Self-testing、B:Independent locking power supply、C:Independent locking output、W:Over-temperature alarm、T:Over-humidity alarm、Z1:DC opening measurement、Z2:DC closing measurement 、M:Analog output、None:no addtional function

    page top