KLD-BMS2000 Series

    High Performance Harmonic Protector

    Filtering harmonic frequency and energy, efficiently controlling harmonic interference, eliminating harmonics at the source.

    PRODUCT OVERVIEW

    Ideal power supply should be a sinusoidal waveform with a single constant frequency and specified amplitude. When a sinusoidal voltage is applied to a non-linear load, the current will be distorted into a non-sinusoidal waveform, which leads to a voltage drop in the grid impedance, making the voltage waveform turn to be non-sinusoidal as well. Applying Fourier series decomposition to non-sinusoidal waveforms, in which the component with the same frequency as the industrial frequency is called the fundamental wave, and the component with a frequency greater than the industrial frequency is called the harmonic wave.

    KLD-BMS2000 series high-performance harmonic protector eliminates harmonics at the power side through digital logics and detects the current waveform generated by non-linear loads in the power grid in real time. It decomposes and reverses the harmonic wave, and then injects the reversed current into the power grid by triggering IGBT inverter to filter out the harmonics. It is mainly applied to the control of harmonics at the power side to protect the important power equipment of customers.

    COMPREHENSIVE HARMONIC
    CONTROL CAPABILITY

    KLD-BMS2000 series high-performance harmonic protector dynamically analyzes system harmonics in real time and filters them out to purify the system, and the response speed is very fast.

    It automatically controls the harmonics according to the situation, and can filter out a wide range of harmonics, including 2nd to 71st harmonics. It can filter out the harmonics of phase A, B and C respectively, and the neutral line has the filtering capacity three times stronger than others, featuring comprehensive high-performance harmonic control.

    MODULAR DESIGN

    KLD-BMS series high-performance harmonic protector adopts modular design with intelligent duct design, featuring lower loss and more convenient application.

    It has complex model structure, wall-mounted and rack-mounted models are all designed in modules. Its compact space design and accurate capacity control can fully meet the needs of different customers, and applicable to a wide range of fields, making it very convenient in the transportation process, capacity increase and maintenance at the later stage. Also, the modular design is easier to be integrated into the power distribution cabinet.

    Technical Parameters

    System voltage 110V~690V
    Rated frequency 50Hz/60Hz(±5%)
    Filter range 2nd-71st harmonics, the order and times of harmonics can be specified
    Response time Transient response time response time≤100ms,F(xiàn)ull response time≤10ms
    Filter effect As high≥97%
    Communication protocol Modbus protocol, RS485/232 module
    Module design Multiple pcs in parallel
    PF adjustment Adjust PF from inductive 0.6 to capacitive 0.6
    Switch frequency 20kHz
    Balance protection Programmable phase balance protection
    Power consumption ≤3% of its power consumption
    Protection degree IP21, high protection kit can be added
    Altitude Conventional 2000 meters, higher altitude can be customized
    Relative humidity ≤95%RH(no condensing)
    Temperature range -40℃~+65℃
    Selection table

    Model Rated Compensation Current(A) Rated voltage(V) Installation method Cooling method
    KLD-BMS2000-50A-400V 50 400 Wall-mounted or rack-mounted Forced air-cooling
    KLD-BMS2000-100A-400V 100 400 Wall-mounted or rack-mounted Forced air-cooling
    KLD-BMS2000-150A-400V 150 400 Wall-mounted or rack-mounted Forced air-cooling
    KLD-BMS2000-200A-400V 200 400 Wall-mounted or rack-mounted Forced air-cooling

    Technical Parameters


    • System voltage:110V~690V

      Rated frequency:50Hz/60Hz(±5%)

      Filtering range:2nd-71st harmonics, the order and times of harmonics can be specified

      Response time:Transient response time response time≤100ms,F(xiàn)ull response time≤10ms

      Filter effect:As high≥97%

      Communication protocol:Modbus protocol, RS485/232 module

      Module design:Multiple pcs in parallel

      PF adjustment:Adjust PF from inductive 0.6 to capacitive 0.6

      Switch frequency:20kHz

      Balance protection:Programmable phase balance protection

      Power consumption:≤3% of its power consumption

      Protection degree:IP21, high protection kit can be added

      Altitude:Conventional 2000 meters, higher altitude can be customized

      Relative humidity:≤95%RH(no condensing)

      Temperature range:-40℃~+65℃

    Selection table


    • KLD-BMS2000-50A-400V

      Rated Compensation Current(A):50

      Rated voltage(V):400

      Installation method:Wall-mounted or rack-mounted

      Cooling method:Forced air-cooling

      KLD-BMS2000-100A-400V

      Rated Compensation Current(A):100

      Rated voltage(V):400

      Installation method:Wall-mounted or rack-mounted

      Cooling method:Forced air-cooling

      KLD-BMS2000-150A-400V

      Rated Compensation Current(A):150

      Rated voltage(V):400

      Installation method:Wall-mounted or rack-mounted

      Cooling method:Forced air-cooling

      KLD-BMS2000-200A-400V

      Rated Compensation Current(A):200

      Rated voltage(V):400

      Installation method:Wall-mounted or rack-mounted

      Cooling method:Forced air-cooling