NYKP Series

    Dual Power Automatic Transfer Switch

    NYKP2 series(16A-3200A)

    NYKP1 series(6A-630A)

    Intelligent Fast Safe Comprehensive

    PRODUCT OVERVIEW

    Dual power automatic transfer switch is a power conversion equipment, featuring fast response, strong stability and high reliability; it has the protection functions for short circuit, grounding, phase loss and over-voltage; widely used in power plants, substations, coal mines, ports, factories, airports, and other important places for the protection of circuits and equipment safety, realizing intelligent control and management.

    FAST RESPONSE AND SWITCHING

    Dual power supplies are driven by motors and solenoids for fast.

    ISOLATION FUNCTION MAKES USERS MORE ASSURED

    The front end of the product can be set with an isolation switch or with isolation function,providing obvious line disconnection points to protect personal safety during maintenance.

    TECHNICAL PARAMETERS

    NYKP2 Series

    • Rated operating voltage: 400V
    • Rated operating current: 16-3200A
    • Product category: PC grade
    • Number of poles: 2P, 3P, 4P
    • Switching mode: automatic charge and automatic recovery, automatic charge without automatic recovery
    • Power supply mode: grid - grid, grid - power generation
    • Use category: AC-33iB, AC-33B

    NYKP1 series

    • Rated operating voltage: 400V
    • Rated operating current: 6-630A
    • Product category: CB grade
    • Number of poles: 3P, 4P
    • Switching mode: automatic charge and automatic recovery, automatic charge without automatic recovery
    • Power supply mode: grid - grid, grid - power generation
    • Use category: AC-33iB
    Technical Parameters

    NYKP2-G Series DUAL Power Supply

    Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit making capacity Icm(kA)Icm(kA) Rated short-time withstand current Icw (kA) Icw(kA) Use category
    NYKP2-GA AC400 100 16、20、25、32、40、50、63、80、100 3P、4P 8 5kA/30ms AC-33B
    NYKP2-GA 250 125、160、200、225、250 10kA/60ms
    NYKP2-GA 630 315、350、400、500、630 12.6kA/60ms
    NYKP2-GA 1600 800、1000、1250、1600 32kA/60ms AC-33iB
    NYKP2-GA 3200 2000、2500、3200 50kA/1s

    NYKP2-LA/L/SA/S Series DUAL Power Supply

    Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit making and Breaking capacity Icm(kA) Operation cycles times/hour Rated short-time withstand current Icw (kA) Icw(kA) Use category
    NYKP2-SA、S、LA、L AC230V(2P), AC400V(3P、4P) 125 20、32、40、50、63、80、 100、125 2P、3P、4P 25 120 10kA/30ms AC-33B
    NYKP2-SA、S、LA、L 250 125、160、200、250 2P、3P、4P 25 10kA/30ms AC-33B
    NYKP2-SA、S、LA、L 630 250、315、400、500、630 2P、3P、4P 30 12.6kA/60ms AC-33B

    NYKP2 Series DUAL Power Controller Summary

    Controller Model NYKP2 Series
    Product model y-701 y-702
    Installation method Split type
    Display mode Indicator light display LCD display
    Rated working system Uninterrupted working system
    Automatic charge and automatic recovery
    Automatic charge without automatic recovery
    Mutual backup
    Automatic start generator function
    Common power supply detection Four-phase power loss detection, three-phase over-voltage and
    Backup power supply detection Four-phase power loss detection, three-phase over-voltage and
    Passive fire protection input
    Active fire protection input (DC9-36V)(DC9-36V)
    Adjustable transfer delay
    Real-time voltage display
    Common and backup power supply indication
    Adjustable overvoltage and undervoltage for common and backup power
    Adjustable start and stop time of generator ●(F/F1)
    Programmable output port
    RS485Electrical energy measurement

    NYKP1 Series DUAL Power Supply

    Model Rated operating voltage Ue(V) Rated impulse withstand voltage Uimp(kV) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit breaking capacity Icn (kA) Rated short-circuit making capacity Icm(kA)Icm(kA) Product code Use category
    NYKP1 AC400 8 63 6、10、16、20、25、 32、40、50、63 3P、4P 5 120 M:Basic type M1: Fire extinguishing type AC-33iB

    NYKP1A Series DUAL Power Supply

    Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Operating mode Transfer time Mechanical life(Times) Electrical life (times) Controller
    NYKP1A AC400 63 6、10、16、20、25、 32、40、50、63 4P R(Automatic charge and automatic recovery)
    S(Automatic charge without automatic recovery)
    F(grid-power generation)
    ≤2s 10000 4500
    NYKP1A 125 63、80、100、125 ≤3s+delay time 7000 3000 W2
    W3
    NYKP1A 250 160、180、200、225、250 5000 2000
    NYKP1A 630 315、350、400、500、630 5000 2000

    NYKP1 Series Dual Power Controller Summary

    Product model NYKP1 Series
    Controller Model W2 W3
    Installation method Split type
    Display mode Digital display LCD display
    Rated working system
    Automatic charge and automatic recovery
    Automatic charge without automatic recovery
    Mutual backup
    Automatic start generator function
    Common power supply detection
    Backup power supply detection
    Passive fire protection input
    Active fire protection input (DC9-36V)(DC9-36V)
    Adjustable transfer delay
    Real-time voltage display
    Common and backup power supply indication
    Adjustable overvoltage and undervoltage for common and backup power
    Adjustable start and stop time of generator
    Programmable output port
    RS485Electrical energy measurement
    Selection table

    NYKP2-G Series DUAL Power Supply

    NYKP2 100 GA 4P 100A RF Additional functions
    Product code Casing current Product category Pole No. Rated current Operating mode Additional functions
    NYKP2:
    Dual power automatic transfer switch
    100A
    250A
    630A
    1600A
    3200A
    GA: Electric motor type
    GA1: Electric motor type
    3P:3 pole
    4P:4 pole
    16A、20A
    25A、32A
    40A、50A
    63A、80A
    100A、125A
    160A、200A
    225A、250A
    315A、350A
    400A、500A
    630A、800A
    1250A
    1600A
    2000A
    2500A
    3200A
    R:Automatic charge and automatic recovery
    S:Automatic charge without automatic recovery
    F:Grid generation
    RF:Automatic charge and automatic recovery+Grid generation
    Y-701
    Y-702

    NYKP2-LA/L/SA/S Series DUAL Power Supply

    NYKP2 125 SA 4P 100A RF Additional functions
    Product code Casing current Product category Pole No. Rated current Operating mode Additional functions
    NYKP2:
    Dual power automatic transfer switch
    125A
    250A
    630A
    SA: Integrated three-section type
    LA: Integrated two-section type
    S:Split three-section type
    L:Split two-section type
    2P:2 pole
    3P:3 pole
    4P:4 pole
    20A、32A、 40A、
    50A、 63A、80A、
    100A、125A、 160A、
    200A、 250A、315A、
    400A、500A、630A
    R:Automatic charge and automatic recovery
    S:Automatic charge without automatic recovery
    F:Grid generation
    RF:Automatic charge and automatic recovery+Grid generation
    Y-701
    Y-702

    Note:?  GA series equipped with standard fire protection function
    ?  GA1 series does not include fire protection function
    ?  GA series with automatic charge without automatic recovery function should be equipped with Y-701/Y-702 controller
    ?   GA series with communication function should be equipped with Y-702 controller

    NYKP1 Series DUAL Power Supply

    NYKP1 63 M 3P 63A RF C type
    Product code Casing current Product category Pole No. Rated current Operating mode Tripping type
    NYKP1:
    Dual power automatic transfer switch
    63A Model M:Basic type
    M1 type:Fire protection type
    3P:3 pole
    4P:4 pole
    6A、10A、 16A、
    20A、 25A、32A、
    40A、50A、 63A
    R:Automatic charge and automatic recovery
    S:Automatic charge without automatic recovery
    F:Grid generation
    RF:Automatic charge and automatic recovery+Grid generation
    C type
    D type

    Note: KLDCB1 is a CB grade dual power supply switch, the execution unit is a miniature circuit breaker, with C characteristics by default

    NYKP1A Series DUAL Power Supply

    NYKP1A 125 4P 63A RF Additional functions
    Product code Casing current Pole No. Rated current Operating mode Additional functions
    NYKP1A:
    Dual power automatic transfer switch
    63A
    125A
    250A
    630A
    4P:4 pole 6A、10A
    16A、20A
    25A、32A
    40A、50A
    63A、80A
    100A、125A
    160A、180A
    200A、225A
    250A、315A
    350A、400A
    500A、630A
    R:Automatic charge and automatic recovery
    S:Automatic charge without automatic recovery
    F:Grid generation
    RF:Automatic charge and automatic recovery+Grid generation
    W2
    W3
    T:Electrical energy measurement

    Note: The execution unit of NYKP1A is a miniature circuit breaker, with C characteristics by default. others are molded case circuit breaker.

    Technical Parameters

    NYKP2-G Series DUAL Power Supply

    • Rated operating voltage (V):AC400

      Current shell frame Inm (A) :16、20、25、32、40、50、63、80、100

      Number of poles:3P、4P

      Rated short-circuit making capacity Icm(kA)lcm(kA):8

      Rated short-time withstand current Icw (kA) Icw(kA):5kA/30ms

      Use category:AC-33B

    • Rated operating voltage (V):AC400

      Current shell frame Inm (A) :125、160、200、225、250

      Number of poles:3P、4P

      Rated short-circuit making capacity Icm(kA)lcm(kA):8

      Rated short-time withstand current Icw (kA) Icw(kA):10kA/60ms

      Use category:AC-33B

    • Rated operating voltage (V):AC400

      Current shell frame Inm (A) :315、350、400、500、630

      Number of poles:3P、4P

      Rated short-circuit making capacity Icm(kA)lcm(kA):8

      Rated short-time withstand current Icw (kA) Icw(kA):12.6kA/60ms

      Use category:AC-33B

    • Rated operating voltage (V):AC400

      Current shell frame Inm (A) :800、1000、1250、1600

      Number of poles:3P、4P

      Rated short-circuit making capacity Icm(kA)lcm(kA):8

      Rated short-time withstand current Icw (kA) Icw(kA):32kA/60ms

      Use category:AC-33iB

    • Rated operating voltage (V):AC400

      Current shell frame Inm (A) :2000、2500、3200

      Number of poles:3P、4P

      Rated short-circuit making capacity Icm(kA)lcn(kA):8

      Rated short-time withstand current Icw (kA) Icw(kA):50kA/1s

      Use category:AC-33iB

    NYKP2-LA/L/SA/S Series DUAL Power Supply

    • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

      Current shell frame Inm (A) :20、32、40、50、63、80、100、125

      Number of poles:2P、3P、4P

      Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):25

      Operation cycles times/hour:120

      Rated short-time withstand current Icw (kA) Icw(kA):10kA/30ms

      Use category:AC-33iB

    • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

      Current shell frame Inm (A) :125、160、200、250

      Number of poles:2P、3P、4P

      Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):25

      Operation cycles times/hour:120

      Rated short-time withstand current Icw (kA) Icw(kA):10kA/30ms

      Use category:AC-33iB

    • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

      Current shell frame Inm (A) :250、315、400、500、630

      Number of poles:2P、3P、4P

      Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):30

      Operation cycles times/hour:120

      Rated short-time withstand current Icw (kA) Icw(kA):12.6kA/60ms

      Use category:AC-33iB

    NYKP2 Series Dual Power Controller Summary

    • Installation method:Split type

      Display mode:Indicator light display

      Rated working system:Uninterrupted working system

      Automatic charge and automatic recovery:have

      Automatic charge without automatic recovery:have

      Mutual backup:have

      Automatic start generator function:have

      Common power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

      Backup power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

      Passive fire protection input:have

      Active fire protection input (DC9-36V):have

      Adjustable transfer delay:have

      Real-time voltage display:not have

      Common and backup power supply indication:have

      Adjustable overvoltage and undervoltage for common and backup power:have

      Adjustable start and stop time of generator:have

      Programmable output port:not have

      RS485 communication function:not have

    • Installation method:Split type

      Display mode:LCD display

      Rated working system:Uninterrupted working system

      Automatic charge and automatic recovery:have

      Automatic charge without automatic recovery:have

      Mutual backup:have

      Automatic start generator function:have

      Common power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

      Backup power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

      Passive fire protection input:have

      Active fire protection input (DC9-36V) :have

      Adjustable transfer delay:have

      Real-time voltage display:have

      Common and backup power supply indication:have

      Adjustable overvoltage and undervoltage for common and backup power:have

      Adjustable start and stop time of generator:have(F/F1)

      Programmable output port:have

      RS485 communication function:have

    NYKP1 Series DUAL Power Supply

    • Rated operating voltage (V):AC400V

      Rated impulse withstand voltage Uimp(kV):8

      Current shell frame Inm (A) :6、10、16、20、25、32、40、50、63

      Number of poles:3P、4P

      Rated ultimate breaking capacity lcm(kA):5

      Rated short-circuit making capacity Icm(kA)lcn(kA):120

      Product code :M: Basic type M1: Fire extinguishing type

      Use category:AC-33iB

    NYKP1A Series DUAL Power Supply

    • Rated operating voltage (V):AC400V

      Rated impulse withstand voltage Uimp(kV):8

      Current shell frame Inm (A) :6、10、16、20、25、32、40、50、63

      Number of poles:4P

      Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

      Transfer time:≤2s

      Mechanical life (times) :10000

      Electrical life (times) :4500

    • Rated operating voltage (V):AC400V

      Rated impulse withstand voltage Uimp(kV):8

      Current shell frame Inm (A) :63、80、100、125

      Number of poles:4P

      Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

      Transfer time:≤3s+delay time

      Mechanical life (times) :7000

      Electrical life (times) :3000

      Controller:W2、W3

    • Rated operating voltage (V):AC400V

      Rated impulse withstand voltage Uimp(kV):8

      Current shell frame Inm (A) :160、180、200、225、250

      Number of poles:4P

      Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

      Transfer time:≤3s+delay time

      Mechanical life (times) :5000

      Electrical life (times) :2000

      Controller:W2、W3

    • Rated operating voltage (V):AC400V

      Rated impulse withstand voltage Uimp(kV):8

      Current shell frame Inm (A) :315、350、400、500、630

      Number of poles:4P

      Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

      Transfer time:≤3s+delay time

      Mechanical life (times) :5000

      Electrical life (times) :2000

      Controller:W2、W3

    NYKP1 Series Dual Power Controller Summary

    • Installation method:Split type

      Display mode:Digital display

      Rated working system:not have

      Automatic charge and automatic recovery:have

      Automatic charge without automatic recovery:have

      Mutual backup:have

      Automatic start generator function:have

      Common power supply detection:have

      Backup power supply detection:have

      Passive fire protection input:have

      Active fire protection input (DC9-36V) :have

      Adjustable transfer delay:have

      Real-time voltage display:have

      Common and backup power supply indication:have

      Adjustable overvoltage and undervoltage for common and backup power:have

      Adjustable start and stop time of generator:have

      Programmable output port:have

      RS485 communication function:have

    • Installation method:Split type

      Display mode:LCD display

      Rated working system:not have

      Automatic charge and automatic recovery:have

      Automatic charge without automatic recovery:have

      Mutual backup:have

      Automatic start generator function:have

      Common power supply detection:have

      Backup power supply detection:have

      Passive fire protection input:have

      Active fire protection input (DC9-36V):have

      Adjustable transfer delay:have

      Real-time voltage display:have

      Common and backup power supply indication:have

      Adjustable overvoltage and undervoltage for common and backup power:have

      Adjustable start and stop time of generator:have

      Programmable output port:have

      RS485 communication function:have

    Selection table


    NYKP2-G Series DUAL Power Supply

    • Product code :NYKP2: Dual power automatic transfer switch

      Current shell frame :100A、250A、630A、1600A、3200A

      Product category :GA、GA1

      Pole code :3P、4P

      Rated current:16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、160A、200A、225A、250A、315A、350A、400A、500A、630A、800A、1250A、1600A、2000A、2500A、3200A

      Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

      Additional features:Y-701、Y-702

    NYKP2-LA/L/SA/S Series DUAL Power Supply

    • Product code :NYKP2: Dual power automatic transfer switch

      Current shell frame :125A、250A、630A

      Product category:SA:Integrated three-section type、LA: Integrated two-section type 、S: Split three-section type、L:Split two-section type

      Pole code :2P、3P、4P

      Rated current: 20A、32A、40A、50A、63A、80A、100A、125A、160A、200A、250A、315A、400A、500A、630A

      Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

      Additional features:Y-701、Y-702

    Note: GA series equipped with standard fire protection function
    GA1 series does not include fire protection function
    GA series with automatic charge without automatic recovery function should be equipped with Y-701/Y-702 controller
    GA series with communication function should be equipped with Y-702 controller

    NYKP1 Series DUAL Power Supply

    • Product code :NYKP1: Dual power automatic transfer switch

      Current shell frame :63A

      Product category:Type M: Basic type、Type M1: Fire protection type

      Pole code :3P、4P

      Rated current:6A、10A、16A、20A、32A、40A、50A、63A

      Operating mode :R:Automatic charge and automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

      Tripping type:Type C 、Type D

    Note: KLDCB1 is a CB grade dual power supply switch, the execution unit is a miniature circuit breaker, with C characteristics by default

    NYKP1A Series DUAL Power Supply

    • Product code :NYKP1A: Dual power automatic transfer switch

      Current shell frame :63A、125A、250A、630A

      Pole code :4P

      Rated current:6A、10A、16A、20A、32A、40A、50A、63A、80A、100A、125A、160A、180A、200A、225A、250A、315A、350A、400A、500A、630A

      Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

      Additional features:W2、W3、T: Communication function

    Note: The execution unit of NYKP1A is a miniature circuit breaker, with C characteristics by default. others are molded case circuit breaker.